Efficient, durable and user-friendly hydronic surface heater
The hydronic surface heater product line is engineered for reliable, trouble free starts even in cold weather conditions. Thawing up to 4,400 sq. ft. of frozen ground, the E2200 can also heat up to 4,400 sq. ft. of ground, indoors or out, to prepare for concrete placement, to prevent frost penetration or to ensure proper concrete curing. With accessories, the E 2200 will provide 360,000 cu. ft. of dry heat, at 87% efficiency, the highest in the industry.
- Feature:
- With 2,200 ft. of hose and a hydraulic hose system, the E 2200 allows for single person set-up and placement, for greater flexibility on all applications.
- Positive displacement pump provides maximum flow and consistent heat delivery for thawing and curing.
- Digital temperature controller with push button adjustment allows operators to easily adjust Heat Transfer Fluid (HTF) output temperature for all concrete curing applications
- Performance monitoring strobe light indicates from a distance that all systems are operating properly.
- Several options are available including a 5 kW liquid-cooled diesel generator and lifting bail.
Interested in this item or want more information?
Hours:
Phone: (301) 773-4700
Email: orders@atlantic-supply.com
Can't find what you want? Give us a call and we can help you find it.
Details
Technical specifications:
| E 2200 | E 2200 W/GENERATOR |
Dimensions |
L x W x H Overall in | 169 x 72 x 88 | 169 x 72 x 88 |
Operating weight lb | 5,490 | 6,006 |
Shipping weight lb | 4,685 | 5,201 |
Heat transfer fluid US gal | 115 | 115 |
Hose Length ft | 2,200 | 2,200 |
Quantity Hose Reels | 1 | 1 |
Hose rewind | 120V AC, w/ 12V DC clutch | 120V AC, w/ 12V DC clutch |
Quantity Circulation Loops | 2 | 2 |
Operating data |
Hose pressure Normal Operating psi | 110 | 110 |
Heating power Gross Input BTU/h | 252,000 | 252,000 |
Heat efficiency % | 87 | 87 |
Operating temperature ° F | 180 | 180 |
Capacity Thaw (Std) ft² | 4,400 | 4,400 |
Capacity Thaw (w/Acc) ft² | 4,400 | 4,400 |
Capacity Cure (Std) ft² | 4,400 | 4,400 |
Capacity Cure (w/Acc) ft² | 13,200 | 13,200 |
Capacity Frost (Std) ft² | 6,600 | 6,600 |
Capacity Frost (w/Acc) ft² | 19,800 | 19,800 |
Capacity Air Heat w/acc ft³ | 360,000 | 360,000 |
Rated current A | 20 | 20 |
Rated voltage V | 115 | 115 |
Fuel type | Winter-Blend Diesel | Winter-Blend Diesel |
Fuel consumption Diesel US gal/h | 1.81 | 2.2 |
Tank capacity Useable Fuel US gal | 115 | 115 |
Runtime @ 100% Burner Run Percentage h | 61 | 50 |
Runtime @ 75% Burner Run Percentage h | 82 | 67 |
Additional Information
Manufacturer: Wacker Neuson