The Beacon 410A is a highly configurable, microprocessor-based, flexible and easy to use 4 channel gas monitoring controller. It simultaneously displays the gas type, readings, and status for four channels of gas detection. It can monitor any combination of direct connect sensors (LEL, O2, CO2, and toxic gas sensors), as well as any 4-20mA transmitter. Each channel has up to three fully configurable alarm points. A built-in silenceable audible alarm alerts you to alarm conditions. Each channel also has two dedicated fully configurable relays and there is a bank of common relays as well. The common relays can optionally be configured as additional relays allowing up to 3 alarm relays per channel. Each channel provides a 4-20mA output signal. A digital Modbus interface for remote logging of data via a Modbus network is standard. A Min-Max feature retains high & low peak readings for review at any time. A fully configurable, high visibility strobe is available as an option. The unit can be powered from 115/220 VAC, or an external 24 VDC source. A trickle charging battery backup feature with battery assembly is also available as an option. All features and functions of the Beacon 410A are controlled by easy to use menus on the OLED display. All features including form-C relay contacts of the Beacon 410A are built into the unit so you never need to purchase or maintain any “add-on” cards or components.

Quick Overview

    Simultaneously control up to 4 gas monitoring channels OLED display of all 4 channels LEL / O2 / CO2 / toxic direct connect sensors Accepts any 4-20 mA transmitter, 2 or 3 wire Up to 3 programmable alarm levels per channel Up to 3 configurable alarm relays per channel 4-20 mA analog & Modbus digital output standard 115 / 220 VAC or 24 VDC operation Audible alarm with silence feature RFI / EMI Resistant Alarm reset switch Built in trouble alarm with relay Weather and corrosion resistant NEMA 4X enclosure
Interested in this item or want more information?

Hours:

Phone: (301) 773-4700

Email: orders@atlantic-supply.com

Can't find what you want? Give us a call and we can help you find it.

Details


Physical

Dimensions Height: 12.5”
Width 11”
Depth 6.4”
Enclosure NEMA 4X non-metallic for indoor and outdoor locations
Conduit
Connection
3/4” NPT conduit hubs, 4 provided, for sensor, power, & relay wiring
Wiring
Termination
Screw type terminal block, 14 gauge max
Power
115 VAC & 220 VAC, or 24 VDC nominal, battery backup option available
Controls
Display PCB Control Switches:
  • UP/YES push button switch
  • DOWN/NO push button switch
  • ESCAPE push button switch
  • ENTER push button switch
  • External reset switch
  • On/Off toggle switch

Environmental

Operating Temp -4°F to 122°F (-20°C to 50°C)
Storage Temp -4°F to 158°F (-20°C to 70°C)
Relative
Humidity
0 - 95% RH (non-condensing)
Enclosure
Rating
NEMA-4X enclosure, chemical and weather resistant

Inputs

Direct Wired
Sensors
LEL, Oxygen, Carbon Monoxide, Hydrogen Sulfide, and Carbon Dioxide.
Remote amp not required for less than 500 feet
4-20 mA Sensors Accepts any 4-20 mA transmitter (24 VDC, 2 or 3 wire). A wide variety of RKI/Riken sensors are available with 4-20 mA signals. Wiring distances up to 8,000 feet
Sampling Methods Diffusion and sample draw heads available

Outputs

Relays Two flexible, programmable Form-C (C, NO, NC) relays per channel, plus five common relays (Fail, Alarm-1, Alarm-2, Alarm-3, Alarm-Any). Common relays may optionally be assigned to function as additional channel alarm relays, providing for up to three alarm relays per channel. 10A contact rating.
4-20 mA Signal output, 4-20 mA (maximum load impedance 500 ohms), per channel
RS-485 Modbus format RS-485 serial output of all channel data, including gas reading and alarm status.
Display Four line OLED display
Audible Built-in audible alarm, 94 dB, mounted on enclosure
Coded output: pulsing = gas alarm, steady = fail
Visual 1. Alarm LEDs (on Display PCB)
  • Alarm 1, yellow
  • Alarm 2, orange
  • Alarm 3, red
  • Fail, yellow
2. Green Pilot LED to indicate AC power connected (on Display PCB)
3. An optional 24 VDC NEMA 4X strobe mounted to top of case.

Warranty

One year materials and workmanship

 

Partial List Of Detectable Gases
Many other gases or ranges available. Contact RKI for gases or ranges not listed.
Ammonia (NH3)
0 - 75.0 ppm
Arsine (AsH3 ) 0 - 0.20 ppm
Boron Trichloride (BCl3) 0 - 15.0 ppm
Carbon Dioxide (CO2) 0 - 1.0 %
Carbon Monoxide (CO) 0 - 300 ppm
Chlorine (Cl2) 0 - 3.0 ppm
Chlorine Dioxide (ClO2) 0 - 1.00 ppm
Chlorine Trifluoride (ClF3) 0 - 1.00 ppm
Combustibles 0 -100% LEL
Diborane (B2H6) 0 - 30.0 ppm
Fluorine (F2) 0 - 6.0 ppm
Hydrogen (H2) 0 - 2000 ppm
Hydrogen Chloride (HCl) 0 - 15.0 ppm
Hydrogen Fluoride (HF) 0 - 9.0 ppm
Hydrogen Sulfide (H2S) 0 -100.0 ppm
Nitric Oxide (NO) 0 -100.0 ppm
Nitrogen Dioxide (NO2) 0 - 15.0 ppm
Nitrogen Trifluoride (NF3) 0 - 30.0 ppm
Oxygen (O2) 0 - 25.0 %
Ozone (O3) 0 - 1.0 ppm
Phosphine (PH3) 0 - 1.0 ppm
Silane (SiH4) 0 - 15.0 ppm
Sulfur Dioxide (SO2) 0 - 30.0 ppm
TEOS (Si(OC2H5)4) 0 -15/30 ppm
Specifications subject to change without notice. 